ESD 44

Order number: 274418

Loop-through box, 2-way - 2 x 4-2400 MHz - Connection loss: VHF/UHF 14.5 dB, sat 15/16 dB

ESD 44
Loop-through box, 2-way - 2 x 4-2400 MHz - Connection loss: VHF/UHF 14.5 dB, sat 15/16 dB more
Product information "ESD 44"
Related links to "ESD 44"

PDF PRODUCT EXPORT

ESD 44

PDF

SPECIAL FEATURES

    • Compliant with: EN 60728-11 and EN 50083-2
    • Stable die-cast housing
    • With screw and claw fastening, suitable for flush mounted boxes with diameter 55-65 mm
    • Can be combined with almost all installation programs
    • Broadband directional coupler outlet (15 dB) for CATV, communal units and satellite house distribution systems, without DC voltage passage
  • Technical data

    Type: ESD 44
    Order no.: 274418
    Connection loss - Radio 5-47 MHz (Return path): 14,5 dB
    Connection loss - Radio 47-68 MHz (Band 1): 14,5 dB
    Connection loss - Radio 87.5-108 MHz (FM): 14,5 dB
    Connection loss - Radio 109³)-470 MHz (VHF): 14,5 dB
    Connection loss - Radio 470-1006 MHz (UHF): 14,5 dB
    Connection loss - Radio 950-2150 MHz (Sat IF): 15 dB
    Connection loss - Radio 2150-2400 MHz (Sat IF): 16 dB
    Connection loss - TV 5-47 MHz (Return path): 14,5 dB
    Connection loss - TV 47-68 MHz (Band 1): 14,5 dB
    Connection loss - TV 87.5-108 MHz (FM): 14,5 dB
    Connection loss - TV 109³)-470 MHz (VHF): 14,5 dB
    Connection loss - TV 470-1006 MHz (UHF): 14,5 dB
    Connection loss - TV 950-2150 MHz (Sat IF): 15 dB
    Connection loss - TV 2150-2400 MHz (Sat IF): 16 dB
    Through loss 5-47 MHz (Return path): 2,0 dB
    Through loss 47-68 MHz (Band 1): 0,8 dB
    Through loss 87.5-108 MHz (FM): 0,8 dB
    Through loss 109³)-470 MHz (VHF): 0,8 dB
    Through loss 470-1006 MHz (UHF): 1,0 dB
    Through loss 950-2150 MHz (Sat IF): 1,6 dB
    Through loss 2150-2400 MHz (Sat IF): 2,2 dB
    Decoupling ¹): Return
    Decoupling ²): Return
    Packaging unit/weight: 10 (50)/1.0-1.1 pc/kg
  • ¹) Between two subscribers
    ²) Between TV and radio connection
    ³) Additional loss at 109 MHz: approx. 2-3 dB

  • Clear Filters

    loading ...

    All Files

    File: ESD 44_84_Bedienungsanleitung_DE_EN_01.2020.pdf

    Category: Bedienungsanleitungen

    Download Link: ESD 44_84_Bedienungsanleitung_DE_EN_01.2020.pdf

    Description: Bedienungsanleitung DE / GB