LCM 50/500m
Order number: 271622
Coaxial cable, Fca, 500 m one-way drum, 12.5mm, PE (bamboo), black, 1nKx Dimensions: 2.2/8.8/12.5 mm, screening factor up to 1000 MHz typical 120 dB - Class A+


PDF PRODUCT EXPORT
SPECIAL FEATURES
- Impedance: 75 Ω
- Inner conductor bare copper; outer conductor welded copper tube
- Very high screening factor typical 120 dB and minimal attenuation values
- Compliant with: EN 50117; screening class A++
- Applications: Underground cable, exterior cable
- Suitable F connectors: EMK 105
Technical data
Type: | LCM 50/500m |
Order no.: | 271622 |
Screening class: | A++ |
Fire classification - Construction Products Regulations 305/2011: | Euro classification Fca |
Installation location: | Indoors, outdoors, ground |
Centre conductor: | 2,2 Cu mm |
Insulation: | 8.8 PE/air (bamboo) mm |
Outer conductor: | 9.3 Cu welded mm |
External sheathing: | 12.5 PE black mm |
Bending radius ¹): | > 150 mm| |
Shortening factor: | 0.89 |
Attenuation at 20 °C (f = 50 MHz): | 1.8 dB/100 m |
Attenuation at 20 °C (f = 100 MHz): | 2.6 dB/100 m |
Attenuation at 20 °C (f = 450 MHz): | 6 dB/100 m |
Attenuation at 20 °C (f = 860 MHz): | 8.7 dB/100 m |
Attenuation at 20 °C (f = 1000 MHz): | 10 dB/100 m |
Attenuation at 20 °C (f = 2150 MHz): | 16.2 dB/100 m |
Attenuation at 20 °C (f = 2400 MHz): | 17.7 dB/100 m |
Return loss 5-470 MHz: | ≥ 28 dB |
Return loss 470-1000 MHz: | ≥ 26 dB |
Return loss 1000-2400 MHz: | ≥ 22 dB |
Screening loss 5-2,400 MHz: | ≥ 120 dB |
Coupling resistance 5-30 MHz: | < 0,1 mOhm/m |
DC resistance: | 5.6 Ω/km |
Max. tensile force: | 350 N |
Postal standard: | Underground cable / 1nKx |
Permissible ambient temperature: | -20 to +50 °C |
Packaging: | 500 m |
Weight (approx.): | 18.5 kg/100m |
ACCESSORIES
loading ...
All Files
File: LCM 50 CE-Etikett.pdf
Category: Erklärungen
Download Link: LCM 50 CE-Etikett.pdf
Description: CE-Etikett LCM 50
File: Leistungserklärung LCM 50.pdf
Category: Erklärungen
Download Link: Leistungserklärung LCM 50.pdf