LCM 33/500m

Order number: 24510061

Coaxial cable, Fca, 500 m one-way drum, 17.3 mm, PE (bamboo), black, 1qKx Dimensions: 3.3/13.4/17.3 mm, screening factor up to 1000 MHz typical 120 dB - Class A+

Coaxial cable, Fca, 500 m one-way drum, 17.3 mm, PE (bamboo), black, 1qKx Dimensions:... more
Product information "LCM 33/500m"
Related links to "LCM 33/500m"

PDF PRODUCT EXPORT

LCM 33/500m

PDF

SPECIAL FEATURES

    • Impedance: 75 Ω
    • Inner conductor bare copper; outer conductor welded copper tube
    • Very high screening factor typical 120 dB and minimal attenuation values
    • Compliant with: EN 50117; screening class A++
    • Applications: Underground cable, exterior cable
    • Suitable F connectors: EMK 104
  • Technical data

    Type: LCM 33/SL
    Order no.: 24510061
    Screening class: A++
    Fire classification - Construction Products Regulations 305/2011: Euro classification Fca
    Installation location: Indoors, outdoors, ground
    Centre conductor: 3,3 Cu mm
    Insulation: 13.5 PE/air (bamboo) mm
    Outer conductor: 14 Cu welded mm
    External sheathing: 17,0 PE schwarz mm
    Bending radius ¹): > 280 mm
    Shortening factor: 0.89
    Attenuation at 20 °C (f = 50 MHz): 1.2 dB/100 m
    Attenuation at 20 °C (f = 100 MHz): 1.7 dB/100 m
    Attenuation at 20 °C (f = 450 MHz): 4 dB/100 m
    Attenuation at 20 °C (f = 860 MHz): 5.5 dB/100 m
    Attenuation at 20 °C (f = 1000 MHz): 7 dB/100 m
    Attenuation at 20 °C (f = 2150 MHz): 10.6 dB/100 m
    Attenuation at 20 °C (f = 2400 MHz): 11.5 dB/100 m
    Return loss 5-470 MHz: ≥ 28 dB
    Return loss 470-1000 MHz: ≥ 26 dB
    Return loss 1000-2400 MHz: ≥ 22 dB
    Screening loss 5-2,400 MHz: ≥ 120 dB
    Coupling resistance 5-30 MHz: < 0,1 mOhm/m
    DC resistance: 2.5 Ω/km
    Max. tensile force: 550 N
    Postal standard: Underground cable / 1qKx
    Permissible ambient temperature: -20 to +50 °C
    Packaging: 500 m
    Weight (approx.): 35 kg/100m