Order number: 21810002

Lightning arrester- Coarse protection for higher leakage currents - 5-2400 MHz - F connectors - Remote feeding < 60 V DC/2 A

KAZ 12 Coarse Protection
Lightning arrester- Coarse protection for higher leakage currents - 5-2400 MHz - F connectors -... more
Product information "KAZ 12 Coarse Protection"
Related links to "KAZ 12 Coarse Protection"

PDF PRODUCT EXPORT

KAZ 12 Coarse Protection

PDF

SPECIAL FEATURES

    • For protection of system components in satellite, CATV and DVB-T reception and distribution systems
    • Using the KAZ 12 increases the surge current discharge capacity of the KAZ 11
    • Can be used as part of a lightning zone concept at LPZ 0A-1 interfaces and higher
    • Compliant with category A2/C2/C3/B2/D1 in accordance with EN 61643-21
    • With gas discharge conductor (over-voltage protection). Gas discharge conductors are the classic over-voltage protection components in coaxial networks
    • Passage for 22 kHz and DiSEqCTM signals
    • For indoor installation
    • Accessories supplied: 1 x EMU 21 earth connection block, 2 x EMK 01 F connector
    • Install coarse protection as close as possible after the house transfer point
  • Technical data

    Type: KAZ 12
    Order no.: 21810002
    Transmission range: 0-2400 MHz
    Through loss: 0.5 dB
    Max. allowable ambient temperature: -40 ... +80 °C|
    RF connections: Input
    Screening factor: 5-300 MHz > 85; 300-470 MHz > 80; 470-1000 MHz > 75; 1000-2400 MHz > 55 dB
    Tested categories in accordance with EN 61643-21: A2/C2/C3/B2/D1
    Lightning surge category D1 (10/350 µs): Inner/outer conductor
    AC load capacity category A2: 10 A
    Nominal discharge surge current (8/20 µs): Inner/outer conductor
    Nominal voltage: 60 V
    Nominal load current (max. allowable remote feed current): 2 A
    Protection level at 10 kA (8/20 µs) category C2: ≤ 700 V
    Protection level at 1 kV/µs category C3: ≤ 600 V
    Protection level at 2.5 kA (10/350 µs) category D1: ≤ 700 V
    Protection level at 6 kV (10/700 µs) category B2: ≤ 600 V
    Response time: ≤ 100 ns
    Housing protection class: IP 30
    DC resistance (input/output): 120 mOhm
    Weight: 0,1 kg