House connection amplifier | 47/85-1006 MHz | F-connector | gain 40/34/30 dB | level control/equalizer: 20 dB | 113/116 dBμV (60dB CTB/CSO, Cenelec 42 Ch.)
- House connection amplifier for modern HFC networks
- Remote powered via RF input (self-powered)
- Latest GaAs MMIC technology
- Very high output level with favorable energy balance
- High efficiency switching power supply
- New innovative operating concept:
– Simplified level adjustment via rotary switch, large adjustment range (20 dB), small step size (1 dB)
– Basic configuration via jumpers
– Precisely reproducible device settings
- Slot for additional functions in the forward path (e.g. deemphasis, system equalizer)
- Gain by interstage attenuation switchable with jumper 40/34/30 dB (delivery condition: 34 dB)
- Diplexer can be bridged (Band I operation possible without return path)
- Return path (active/passive/disconnectable) with various setting options permanently integrated
- Classification according to KDG 1 TS 140: Type D(4.4)
- Test sockets (F-connectors):
– Bidirectional at the input (can be switched on)
– With directional coupler at the output
- Internal LED function indicator
- Overvoltage arrester at input and output
- Complies: EN 60728-11, EN 50083-2 and EN 62368-1
- Cast housing with F connections
- For use in locations protected from the weather
- The amplifier complies with the requirements of the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU valid at the time of delivery
Type: |
VOS 138/RA 2.0 |
Bestell-Nr.: |
209500004 |
Vodafone-/KDG-Freigabe: |
ja |
Vorwärtsweg: |
—————————————————– |
Frequency range 1): |
47/85-1006 MHz |
Gain: |
40/34/30 dB |
Attenuator setting range: |
0-20 dB |
Equalizer setting range : |
0-20 dB |
Interstage attenuation setting range: |
0-20 dB |
Interstage equalization adjustment range: |
0/3/6 dB, 0/6 dB |
Maximum operating level at 862 MHz 2) with 6 dB interstage preemphasis (60 dB CTB/CSO): |
113/116 dBµV |
Noise figure (interstage attenuation 0/6/10 dB): |
Type. 6/7/7 dB |
Rückweg: |
—————————————————– |
Frequency range: |
5-65 MHz |
Gain active/passive: |
30 dB/-2 dB |
Input attenuation setting range: |
0/10 dB |
Input equalization setting range: |
0/3 dB |
Interstage attenuation adjustment range: |
0-20 dB |
Interstage equalization adjustment range: |
0/3/6 dB |
Max. Output level (60-dB-IMA2/IMA3) |
107/116 dB |
Output capability KDG 1 TS 140 (full system load): |
120 dBµV |
Noise Measure: |
Type. 5 dB |
Input level density (CINR at 50 dB, EN 60728-3; 4.7): |
-10 dBµV/Hz |
Dynamic range (EN 60728-3; 4.7): |
17 dB |
Test sockets (F-Connector) |
—————————————————– |
Amplifier input (5-1006 MHz, bidirectional): |
-20 dB |
Amplifier output (5-1006 MHz, with directional coupler): |
-20 dB |
Schaltnetzteil: |
—————————————————– |
Nominal input voltage: |
32-65 V∼ (50/60 Hz) |
Typical nominal input power 3) |
Return path passive or deactivated: |
14 W |
Return path active: |
15 W |
Allgemeines: |
—————————————————– |
Impedance input/output: |
75 Ω |
HF-Anschlüsse: |
F-Connector |
Protection class (to EN 60529) 4): |
IP 54 |
Temperature range: |
-20 to +55 °C |
Dimensions: |
218 x 150 x 80 mm |
Packaging unit/weight: |
1 (10)/1.25 pcs/kg |
Classification according to KDG 1 TS 140: |
Type D (4.4) |
1) Frequency range from 47 MHz without return path use
2) According to EN 60728-3; CENELEC grid with 42 beams
3) VOS 138/RA 2.0 and VOS 139/RA 2.0: Nominal input power as a function of the feed-in voltage during operation via the cable resistor
4) Outdoor use in weather-protected cabinets only.