House connection amplifier | 47/85 – 1006 MHz | PG 11 | Gain 40/34/30 dB | Level control/equalizer: 20 dB | 113/116 dBµV (60dB CTB/CSO, Cenelec 42 Ch.)
- House connection amplifier for modern HFC networks
- Remote powered via RF input (self-powered)
- Latest GaAs MMIC technology
- Very high output level with favorable energy balance
- High efficiency switching power supply
- New innovative operating concept:
- Simplified leveling via rotary switch, large setting range (20 dB), small step size (1 dB)
- Basic configuration via jumpers
- Exactly reproducible device settings
- Slot for additional functions in the forward path (e.g. deemphasis, system equalizer)
- Gain by interstage attenuation switchable with jumper 40/34/30 dB (delivery condition: 34 dB)
- Diplexer can be bridged (Band I operation possible without return path)
- Return path (active/passive/disconnectable) with various setting options permanently integrated
- Classification according to KDG 1 TS 140: Type D(4.4)
- Test sockets (F-connectors):
- Bidirectional at input (switchable)
- With directional coupler at output
- Internal LED function indicator
- Overvoltage arrester at input and output
- Complies: EN 60728-11, EN 50083-2 and EN 62368-1
- Cast housing with F connections (VOS 137/RA 2.0, VOS 138/RA 2.0) or PG 11 connections (VOS 139/RA 2.0: order cable fittings separately, not included in scope of delivery)
- For use in locations protected from the weather
- The amplifier complies with the requirements of the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU valid at the time of delivery
| Type: |
VOS 139/RA 2.0 |
| Order no: |
209500005 |
| Vodafone/KDG release: |
yes |
| Forward path: |
—————————————————– |
| Frequency range 1): |
47/85-1006 MHz |
| Gain: |
40/34/30 dB |
| Attenuator setting range: |
0-20 dB |
| Equalizer setting range : |
0-20 dB |
| Interstage attenuation adjustment range: |
0-20 dB |
| Interstage equalization adjustment range: |
0/3/6 dB, 0/6 dB |
| Maximum operating level at 862 MHz 2) with 6 dB interstage preemphasis (60 dB CTB/CSO): |
113/116 dBµV |
| Noise figure (interstage attenuation 0/6/10 dB): |
Type. 6/7/7 dB |
| Way back: |
—————————————————– |
| Frequency range: |
5-65 MHz |
| Gain active/passive: |
30 dB/-2 dB |
| Input attenuation setting range: |
0/10 dB |
| Input equalization setting range: |
0/3 dB |
| Interstage attenuation adjustment range: |
0-20 dB |
| Interstage equalization adjustment range: |
0/3/6 dB |
| Max. Output level (60-dB-IMA2/IMA3) |
107/116 dB |
| Output capability KDG 1 TS 140 (full system load): |
120 dBµV |
| Noise Measure: |
Type. 5 dB |
| Input level density (CINR at 50 dB, EN 60728-3; 4.7): |
-10 dBµV/Hz |
| Dynamic range (EN 60728-3; 4.7): |
17 dB |
| Test sockets (F-Connector) |
—————————————————– |
| Amplifier input (5-1006 MHz, bidirectional): |
-20 dB |
| Amplifier output (5-1006 MHz, with directional coupler): |
-20 dB |
| Switching power supply: |
—————————————————– |
| Nominal input voltage: |
32-65 V∼ (50/60 Hz) |
| Typical nominal input power 3) |
| Return path passive or deactivated: |
14 W |
| Return path active: |
15 W |
| General information: |
—————————————————– |
| Impedance input/output: |
75 Ω |
| HF connections: |
PG 11 |
| Remote supply current load capacity: |
5 A |
Hum modulation distance (forward path/
return path): |
60/70 dB |
| Protection class (to EN 60529) 4): |
IP 54 |
| Temperature range: |
-20 to +55 °C |
| Dimensions: |
218 x 150 x 80 mm |
| Packaging unit/weight: |
1 (10)/1.25 pcs/kg |
| Classification according to KDG 1 TS 140: |
Type D (4.4) |
1) Frequency range from 47 MHz without return path use
2) According to EN 60728-3; CENELEC grid with 42 beams
3) VOS 138/RA 2.0 and VOS 139/RA 2.0: Nominal input power as a function of the feed-in voltage during operation via the cable resistor
4) Outdoor use in weather-protected cabinets only.