VOS 43/RA-1G2

House connection amplifier up to 1.2 GHz

Sources of supply
Info and addresses
Do you have a question about the product?
Then use our support form...
  • House connection amplifier for modern HFC networks up to 1.2 GHz
  • Built-in high-efficiency switching power supply
  • Power management: switching off amplifier stages that are not required to reduce power consumption
  • Cast housing with F connections
  • Gain switchable via 6 dB interstage attenuation with jumpers (delivery status: higher gain)
  • The maximum operating levels also apply when interstage attenuation is switched on
  • Interstage equalizer switchable with jumpers (6 dB preemphasis)
  • Integrated return path 5 – 204 MHz active/passive and switchable (switchable with jumpers)
  • Permanently installed, adjustable attenuators (return path as supplied: max. attenuation) and adjustable equalizers
  • LED as operating indicator
  • Test socket at output -20 dB (with directional coupler)
  • Test socket at input -20 dB (return path 5 – 204 MHz)
  • Test sockets terminated with EMK 03 in as-delivered condition
  • For indoor installation
  • Fulfill: EN 60728-11, EN 50083-2 and EN 62368-1
  • The amplifier complies with the requirements of the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU valid at the time of delivery
Type: VOS 43/RA-1G2
Order no: 209500001
Forward path: —————————————————–
Frequency range: 258 – 1218 MHz
Gain (switchable via interstage attenuation): 34 | 40 dB
Amplitude ripple: ± 1 | ± 1.5 dB
Setting range attenuation adjuster: 0 – 20 dB
Equalizer setting range: 0 – 15 dB
Interstage attenuation setting range (switchable with jumper): 0 | 6 dB
Interstage equalizer setting range (switchable with jumper): 0 | 6 dB
Maximum operating level 1) (60-dB-CTB/CSO)
flat:
with intersatage preemphasis:
108 | 114 dBµV
110 | 116 dBµV
Maximum operating level 2) (BER <1E-9)
flat:
with interstage preemphasis:
103 dBµV
105 dBµV
Noise figure (interstage attenuation 0/6 dB): 5 | 6 dB
Number of outputs: 1
Way back: —————————————————–
Frequency range: 5 – 204 MHz
Gain (switchable passive/active): -1/28 dB and can be switched off
Setting range attenuation at the input of the amplifier (switchable with jumper): 0 | 10 dB
Adjustment range attenuator (output of the amplifier): 0 – 20 dB
Equalizer setting range (output of the amplifier): 0 – 20 dB
Noise figure: 5 dB
Input level density (CINR: 50 dB): -11 dBµV/Hz
Dynamic range (input level density): 21 dB
Maximum operating level (BER <1E-9) 24 channels QAM 256: 106 dBµV
General information: —————————————————–
Impedance input/output: 75 Ω
Return loss input/output
Forward path 3)
Return path
18 dB
20 dB
HF connections: F-Connector
Test socket output with directional coupler (5 – 1218 MHz) -20 dB
Test socket output return path (5 – 204 MHz) -20 dB
Nominal input voltage: 230 (50/60 Hz) VAC
Power consumption (without | with return path) 6 | 8 W
Power indicator: LED green
Protection class/protection type (according to EN 60529): II/IP 50
Temperature range: -20 to +55 °C
Dimensions: 184 x 134 x 63 mm
Packaging unit/weight: 1 (10)/1.7 pcs/kg

1) According to EN 60728-3; CENELEC grid 34 carriers; level values also apply when interstage attenuation is switched on
2) According to EN 60728-3 119 channels 256 QAM
3) According to EN 60728-3 (category B); from 40 MHz 18 dB -1.5 dB/octave

    * required

    Company / Business

    Mr.Mrs.

    First name *

    Name *

    eMail *

    Product*

    Item no.*

    Your question about the product

    Read & Accepted Privacy policy

    ... from the same product category & recommendations

    Kathrein highlights & bestsellers

    House connection amplifier up to 1.2 GHz
    Surge protection for data networks and Ethernet applications
    Wideband optical receiver with terrestrial output
    Universal Quattro Feed System