- Cascadable multiswitch for distribution of four satellite levels and terrestrial signals to many receivers
- Only one line is required per receiver (two lines for twin receivers)
- Independent horizontal/vertical, low/high selection from any receiver
- Switching takes place via the coaxial cable with 14/18 V and 0/22 kHz signal frequency
- Integrated amplifier for low connection losses in the satellite range
- Preemphasis for equalization of cable attenuation integrated
- Reception of the terrestrial range possible even when the satellite receiver is switched off
- Terrestrial range: 5-862 MHz passive
- High decoupling between outputs
- For indoor installation
- Through-connection multi-switch for system expansion by 16 connections each
- Up to six devices can be cascaded
- Kathrein Power Saving:
As soon as no receiver is active, a signal is sent to the end multi-switch via the trunk vertical low, which then switches off the LNB voltage supply
Home | Products | TV reception / distribution | SAT ZF Distribution Technology | Multi Switches | Cascadable | EXR 25516
EXR 25516
Multiswitch with 16 connections
Order Nr..
205500007
Categories Cascadable, Multi Switches, SAT ZF Distribution Technology, TV reception / distribution
Tag 2ndLevel NO CART
Kaufen Sie dieses Produkt, um 14700 Kathrein JOIN Punkte zu sammeln. Jetzt kostenlos anmelden und Mein Kathrein Konto anlegen und die ersten 10.000 Punkte sichern !
Type: | EXR 25516 |
Order no: | 205500007 |
Subscriber lines: | 16 |
Inputs: | 1 x terr. | 4 x Sat IF |
Frequency ranges: | 5 – 862 MHz | 950 – 2150 MHz |
Throughput attenuation: | 4 / 3 → 6 dB |
Connection attenuation subscriber 1 – 8 ¹): | 18 → 20 dB | 5 → 1 dB |
Connection attenuation Participants 9 – 16 ¹): | 22 → 25 dB | 5 → 1 dB |
Decoupling horizontal → vertical: | 25 dB |
Decoupling participants: | 40 / 25 dB |
Decoupling strain: | 40 dB |
Max. Output level ²): | 109 dBµV |
Control input vert./horiz: | 12 – 14 V | 16 – 19 V |
Control low/high band: | 0/22 kHz |
Current consumption/participant: | 20 mA |
Protection class: | IP 30 |
Max. permissible remote supply current per trunk: | 800 mA |
Connections: | F-Connectors |
Permissible ambient temperature: | -20 to +55 °C |
Dimensions (W x H x D): | 239 x 148 x 43 mm |
Packaging unit/weight: | 1 (10)/0.33 pcs./kg |
¹) Frequency-dependent attenuation