- For distribution of four satellite levels and terrestrial signals to 12 connections
- Only one line is required per receiver (two lines for twin receivers)
- Independent horizontal/vertical, low/high selection from any receiver
- Switching takes place via the coaxial cable with 14/18V and 0/22 kHz signal frequency
- With integrated amplifier for low connection attenuation in the satellite and terrestrial range
- Preemphasis for equalization of cable attenuation integrated
- Reception of the terrestrial range possible even when the satellite receiver is switched off
- High decoupling between outputs
- LNB remote power supply possibility via the input horizontal low. All other inputs are voltage-free
- High-efficiency NCF 18 plug-in power supply with integrated EMC protection
- For indoor installation
- Notice:
For larger installations, the cascadable Sat IF distribution system with the components EXR 2508, EXR 2554, EXR 2558 and VWS 2551 is available
Home | Produkte | TV reception / distribution | SAT ZF Distribution Technology | Multi Switches | Not cascadable | EXR 1512
EXR 1512
Multiswitch with 12 connections
Order Nr..
20510013
Categories TV reception / distribution, Multi Switches, Not cascadable
Tag 2ndLevel NO CART
| Type: | EXR 1512 |
| Order no: | 20510013 |
| Subscriber lines: | 12 |
| Inputs: | 1 x terr. | 4 x Sat IF |
| Frequency ranges: | 47 – 862 MHz | 950 – 2150 MHz |
| Connection attenuation ¹): | 8 → 4 dB | 12 → 7 dB |
| Decoupling horizontal → vertical: | 25 dB |
| Decoupling participants: | 25 / 25 dB |
| Max. Output level ²): | 89 / 105 dBµV |
| Control input vert./horiz: | 12 – 14.5 V | 16 – 19 V |
| Control low/high band: | 0/22 kHz |
| Current consumption/participant: | < 25 mA |
| Permissible input voltage range: | 198 – 253 V |
| Nominal input voltage: | 230 V (47 – 63 Hz) |
| Nominal input power at 0 mA | 150 mA | 550 mA load: | 3.4 W | 6.3 W | 15 W |
| Voltage secondary ³): | 18 V |
| Max. Total remote power supply current ³): | 550 mA |
| Protection class | Protection class: | II (protective insulation) | IP 30 |
| Connections: | F-Connectors |
| Zul. Ambient temperature: | -20 to +55 °C |
| Dimensions (W x H x D): | 239 x 148 x 43 mm |
| Packaging unit/weight: | 1 (10)/0.3 pcs./kg |
¹) Frequency-dependent attenuation (pre-emphasis)
²) Terr. according to EN 50083-5, 60-dB-KMA; SAT according to EN 60728-3, 35-dB-IMA
³) Via input horizontal low
- EXR 1512 - EU-Konformitätserklärung (Version: konformitätserklärung_exr 1512 - Größe: 95.17 KB) (76 downloads)
- EXR 1512 - Produktdatenblatt (Version: 08/2023 - Größe: 136.56 KB) (336 downloads)
- EXR 156/158/1512/1516 - Bedienungsanleitung (Version: 1 - Größe: 661.73 KB) (6204 downloads)