- For distribution of four satellite levels and terrestrial signals to 6 ports
- Only one line is required per receiver (two lines for twin receivers)
- Independent horizontal/vertical, low/high selection from any receiver
- Switching takes place via the coaxial cable with 14/18V and 0/22 kHz signal frequency
- With integrated amplifier for low connection attenuation in the satellite and terrestrial range
- Preemphasis for equalization of cable attenuation integrated
- Reception of the terrestrial range possible even when the satellite receiver is switched off
- High decoupling between outputs
- LNB remote power supply possibility via the input horizontal low. All other inputs are voltage-free (thus operation with UAS 585 possible).
- Low power consumption due to highly efficient, short-circuit-proof switched-mode power supply and power-saving concept (each individual multiswitch branch is supplied by the connected receiver and switched off when the receiver is switched off)
- For indoor installation
- Notice:
For larger installations, the cascadable Sat IF distribution system with the components EXR 2508, EXR 2554, EXR 2558 and VWS 2551 is available
Home | Products | TV reception / distribution | SAT ZF Distribution Technology | Multi Switches | Not cascadable | EXR 156
EXR 156
Multiswitch with 6 connections
Order Nr..
20510011
Categories Multi Switches, Not cascadable, TV reception / distribution
Tag 2ndLevel NO CART
Kaufen Sie dieses Produkt, um 12900 Kathrein JOIN Punkte zu sammeln. Jetzt kostenlos anmelden und Mein Kathrein Konto anlegen und die ersten 10.000 Punkte sichern !
Type: | EXR 156 |
Order no: | 20510011 |
Subscriber lines: | 6 |
Inputs: | 1 x terr. | 4 x Sat IF |
Frequency ranges: | 47 – 862 MHz | 950 – 2150 MHz |
Connection attenuation ¹): | 4 → 0 dB | 12 → 7 dB |
Decoupling horizontal → vertical: | 25 dB |
Decoupling participants: | 25 / 25 dB |
Max. Output level ²): | 95 / 105 dBµV |
Control input vert./horiz: | 12 – 14.5 V | 16 – 19 V |
Control low/high band: | 0/22 kHz |
Current consumption/participant: | < 25 mA |
Permissible input voltage range: | 198 – 253 V |
Nominal input voltage: | 230 V (47 – 63 Hz) |
Nominal input power at 0 mA | 150 mA | 550 mA load: | 3.4 W | 6.3 W | 15 W |
Voltage secondary ³): | 18 V |
Max. Total remote power supply current ³): | 550 mA |
Protection class | Protection class: | II (protective insulation) | IP 30 |
Connections: | F-Connectors |
Zul. Ambient temperature: | -20 to +55 °C |
Dimensions (W x H x D): | 215 x 148 x 43 mm |
Packaging unit/weight: | 1 (10)/0.65 pc/kg |
¹) Frequency-dependent attenuation (pre-emphasis)
²) Terr. according to EN 50083-5, 60-dB-KMA; SAT according to EN 60728-3, 35-dB-IMA
³) Via input horizontal low
- EXR 156 - EU-Konformitätserklärung (Version: konformitätserklärung_exr 156 - Größe: 95.02 KB) (36 downloads)
- EXR 156 - Product data sheet (Version: 08/2023 - Größe: 140.29 KB) (37 downloads)
- EXR 156 - Produktdatenblatt (Version: 08/2023 - Größe: 139.61 KB) (221 downloads)
- EXR 156/158/1512/1516 - Bedienungsanleitung (Version: 1 - Größe: 661.73 KB) (4854 downloads)
... from the same product category & recommendations
House connection amplifier 47/85-1006 MHz | remotely powered via RF input (self-supply)