Coaxial cable, Eca, 7 mm | White PVC | Shielding effectiveness typ. 90 dB | Meter markings | Attenuation/100 m: 18,4 dB (860 MHz), 30,5 dB (2150 MHz)
- Impedance: 75 Ω
- Insulation made of a special PE mixture, foamed by gas injection
- meter marking
- Lead-free and silicone-free
- Complies with: EN 50117
- For home installation
- Fire class according to BauPVO (EN 50575): Eca
- Suitable plugs: EMK 01, EMK 02, EMK 11, EMK 12, EMK 20 plus, EMK 62, EMK 63, EMK 64
| Type: | LCD 130 A+ |
| Vodafone/KDG approval: | ja |
| Shielding class: | A ++ |
| Fire class – BauPVO 305/2011: | Euroclass B2ca s1a d0 a1 |
| Installation area: | Inside |
| Inner conductor: | 1,13 mm Cu |
| Insulation: | 4,8 mm PE |
| External conductor: | 2 x Al/pet film – 1 x CuSn braid |
| Outer shell: | 6,9 mm HFFR white |
| Bending radius: | > 35 mm |
| Typical shortening factor: | 0.85 |
| Attenuation at 5 MHz: | 1 dB/100 m |
| Attenuation at 50 MHz: | 4,1 dB/100 m |
| Attenuation at 100 MHz: | 5,7 dB/100 m |
| Attenuation at 450 MHz: | 12 dB/100 m |
| Attenuation at 860 MHz: | 17,1 dB/100 m |
| Attenuation at 1000 MHz: | 18,5 dB/100 m |
| Attenuation at 2150 MHz: | 28,4 dB/100 m |
| Attenuation at 2400 MHz: | 29,9 dB/100 m |
| Return loss 5 – 470 MHz: | > 26 dB |
| Return loss 470 – 862 MHz: | > 25 dB |
| Return loss 862 – 1000 MHz: | > 23 dB |
| Return loss 1000 – 2150 MHz: | > 20 dB |
| Shielding attenuation 30 – 3000 MHz typ.: | 130 dB |
| Coupling resistance 5 – 30 MHz: | ≤ 0,9 mΩ/m |
| DC resistance: | < 30 Ω/km |
| Max. permissible tensile force: | 120 N |
| Permissible ambient temperature (installation): | -25 to +70 °C |
| Weight approx.: | 5,1 kg/100 m |