Coaxial cable Fca | 11,0 mm | PE (Bamboo) | black | 1iKx – Dimensions: 1,1/7,3/11,0 mm | Shielding effectiveness up to 1000 MHz typ. 120 dB | Shielding class A++
- Impedance: 75 Ω
- Inner conductor: bare copper; outer conductor: welded copper tube
- Very high shielding effectiveness, typically 120 dB, and extremely low attenuation values.
- Complies with: EN 50117; Shielding class: Class A++
- Application: Underground cables, outdoor cables
- Suitable F-connectors: EMK 106
| Type: | LCM96 |
| Vodafone/KDG approval: | no |
| Shielding class: | A ++ |
| Fire class – BauPVO 305/2011: | Euroclass FCA |
| Installation area: | Inside, outside, earth |
| Inner conductor: | 1,1 mm Cu |
| Insulation: | 7,3 mm PE (cell edge) |
| External conductor: | 7,8 mm welded copper |
| Outer shell: | 11,0 mm PE black |
| Bending radius ¹): | > 150 mm |
| Shortening factor: | 0.66 |
| Attenuation at 20 °C (f = 50 MHz): | 3,6 dB/100 m |
| Attenuation at 20 °C (f = 100 MHz): | 5,2 dB/100 m |
| Attenuation at 20 °C (f = 450 MHz): | 12 dB/100 m |
| Attenuation at 20 °C (f = 860 MHz): | 17 dB/100 m |
| Attenuation at 20 °C (f = 1000 MHz): | 18,5 dB/100 m |
| Attenuation at 20 °C (f = 2150 MHz): | 29,4 dB/100 m |
| Attenuation at 20 °C (f = 2400 MHz): | 31,7 dB/100 m |
| Return loss 5 – 470 MHz: | ≥ 28 dB |
| Return loss 470 – 1000 MHz: | ≥ 26 dB |
| Return loss 1000 – 2400 MHz: | ≥ 22 dB |
| Shielding attenuation 5 – 2400 MHz: | ≥ 120 dB |
| Coupling resistance 5 – 30 MHz: | < 0,1 mΩ/m |
| DC resistance: | 25,5 Ω/km |
| Max. tensile force: | 300 N |
| Postnorm: | Underground cable/ 1iKx |
| Permissible ambient temperature: | -20 to +50 °C |
| Weight approx.: | 15 kg/100m |