ESU 36

Order number: 21110022

Loop-through box for unicable system - 3-way - 87-108 and 47-68/118-862 and 950-2150 MHz - DC voltage passage via satellite - Connection loss: FM 11 dB, VHF/UHF/sat 10 dB

ESU 36
Loop-through box for unicable system - 3-way - 87-108 and 47-68/118-862 and 950-2150 MHz - DC... more
Product information "ESU 36"
Related links to "ESU 36"

PDF PRODUCT EXPORT

ESU 36

PDF

SPECIAL FEATURES

    • Compliant with: EN 60728-11 and EN 50083-2
    • Switches off the connected receiver if it is not using the unicable DiSEqCTM command set in accordance with EN 50494 or EN 50607 (switches off voltage from satellite connection to input at +18 V after approx. 400 ms)
    • Overload protection with electronic fuse and decoupling diodes
    • ERA 14 to be used as the terminating resistor
    • Stable die-cast housing
    • With screw and claw fastening, suitable for flush mounted boxes with Ø 55-65 mm
    • Can be combined with almost all installation programs
    • Connections: TV - IEC connector | Radio - IEC socket | Sat IF - F socket
    • Directional coupler outlet, 3-way, for loop-through systems in unicable systems complying with EN 50494 or EN 50607.
    • With DC voltage passage to trunk line via satellite connection (max. 24 V/400 mA, 22 kHz and DiSEqCTM-Signal)
  • Technical data

    Type: ESU 36
    Order no.: 21110022
    Connection loss - Radio 47-68 MHz (Band I): - dB
    Connection loss - Radio 87.5-108 MHz (FM): 15 dB
    Connection loss - Radio 118-470 MHz (VHF): - dB
    Connection loss - Radio 470-862 MHz (UHF): - dB
    Connection loss - Radio 950-2150 MHz (Sat IF): - dB
    Connection loss - TV 47-68 MHz (Band I): 14 dB
    Connection loss - TV 87.5-108 MHz (FM): - dB
    Connection loss - TV 118-470 MHz (VHF): 14 dB
    Connection loss - TV 470-862 MHz (UHF): 14 dB
    Connection loss - TV 950-2150 MHz (Sat IF): - dB
    Connection loss - Sat IF 47-68 MHz (Band I): - dB
    Connection loss - Sat IF 87.5-108 MHz (FM): - dB
    Connection loss - Sat IF 118-470 MHz (VHF): - dB
    Connection loss - Sat IF 470-862 MHz (UHF): - dB
    Connection loss - Sat IF 950-2150 MHz (Sat IF: 14 dB
    Through loss VHF: 0,7 dB
    Through loss UHF: 0,8 dB
    Through loss Sat-IF: 1,5 dB
    Internal decoupling ¹) Sat IF: > 32 dB
    Internal decoupling ¹) VHF/UHF: > 42 dB
    Packaging unit/weight: 10 (50)/1.0 pc/kg
  • ¹) Between two subscribers

  • Clear Filters

    loading ...

    All Files

    File: ESU 3X Bedienungsanleitung_07.19.pdf

    Category: Bedienungsanleitungen

    Download Link: ESU 3X Bedienungsanleitung_07.19.pdf

    Description: ​Bedienungsanleitung Deutsch / Englisch