- For distribution of four satellite levels and terrestrial signals to 6 ports
- Only one line is required per receiver (two lines for twin receivers)
- Independent horizontal/vertical, low/high selection from any receiver
- Switching takes place via the coaxial cable with 14/18V and 0/22 kHz signal frequency
- With integrated amplifier for low connection attenuation in the satellite and terrestrial range
- Preemphasis for equalization of cable attenuation integrated
- Reception of the terrestrial range possible even when the satellite receiver is switched off
- High decoupling between outputs
- LNB remote power supply possibility via the input horizontal low. All other inputs are voltage-free (thus operation with UAS 585 possible).
- Low power consumption due to highly efficient, short-circuit-proof switched-mode power supply and power-saving concept (each individual multiswitch branch is supplied by the connected receiver and switched off when the receiver is switched off)
- For indoor installation
- Notice:
For larger installations, the cascadable Sat IF distribution system with the components EXR 2508, EXR 2554, EXR 2558 and VWS 2551 is available
Home | Products | TV reception / distribution | SAT ZF Distribution Technology | Multi Switches | Not cascadable | EXR 156
EXR 156
Multiswitch with 6 connections
Order Nr..
20510011
Categories TV reception / distribution, Multi Switches, Not cascadable
Tag 2ndLevel NO CART
Kaufen Sie dieses Produkt, um 12900 Kathrein JOIN Punkte zu sammeln. Jetzt kostenlos anmelden und Mein Kathrein Konto anlegen und die ersten 10.000 Punkte sichern !
Type: | EXR 156 |
Order no: | 20510011 |
Subscriber lines: | 6 |
Inputs: | 1 x terr. | 4 x Sat IF |
Frequency ranges: | 47 – 862 MHz | 950 – 2150 MHz |
Connection attenuation ¹): | 4 → 0 dB | 12 → 7 dB |
Decoupling horizontal → vertical: | 25 dB |
Decoupling participants: | 25 / 25 dB |
Max. Output level ²): | 95 / 105 dBµV |
Control input vert./horiz: | 12 – 14.5 V | 16 – 19 V |
Control low/high band: | 0/22 kHz |
Current consumption/participant: | < 25 mA |
Permissible input voltage range: | 198 – 253 V |
Nominal input voltage: | 230 V (47 – 63 Hz) |
Nominal input power at 0 mA | 150 mA | 550 mA load: | 3.4 W | 6.3 W | 15 W |
Voltage secondary ³): | 18 V |
Max. Total remote power supply current ³): | 550 mA |
Protection class | Protection class: | II (protective insulation) | IP 30 |
Connections: | F-Connectors |
Zul. Ambient temperature: | -20 to +55 °C |
Dimensions (W x H x D): | 215 x 148 x 43 mm |
Packaging unit/weight: | 1 (10)/0.65 pc/kg |
¹) Frequency-dependent attenuation (pre-emphasis)
²) Terr. according to EN 50083-5, 60-dB-KMA; SAT according to EN 60728-3, 35-dB-IMA
³) Via input horizontal low
- EXR 156 - EU-Konformitätserklärung (Version: konformitätserklärung_exr 156 - Größe: 95.02 KB) (26 downloads)
- EXR 156 - Product data sheet (Version: 08/2023 - Größe: 140.29 KB) (29 downloads)