- Distribution network amplifier for satellite and terrestrial range in Kathrein satellite IF distribution system 4 x satellite IF
- Five amplifiers (4 x Sat IF and 1 x terrestrial range) are housed in one cabinet
- High modulation stability of the amplifier trains
- High decoupling between the amplifier trains
- BK suitability of the terrestrial amplifier train by GaAs output stage
- For indoor installation
- Stepwise adjustable attenuation controls (1-dB step) in each amplifier strip for leveling different input levels
- Fixed pre-equalization in the terrestrial amplifier train
- Stepwise adjustable pre-equalization (2/4/6 dB) in each satellite amplifier train
- Low power consumption due to highly efficient, short-circuit-proof switching power supply unit
- LNB remote power supply possibility via the input horizontal low. All other inputs are voltage-free (thus operation with UAS 585 possible)
- Kathrein Power Saving: In systems that support Kathrein Power Saving (KPS), the LNB supply is switched off as soon as no receiver is in operation.
Home | Products | TV Empfang / Verteilung | SAT-ZF-Verteiltechnik | Multischalter | Kaskadierbar | VWS 2500
VWS 2500
Multiswitch distribution network amplifier
Order Nr..
20510098
Categories Cascadable, Multi Switches, SAT ZF Distribution Technology, TV reception / distribution
Tag 2ndLevel NO CART
Kaufen Sie dieses Produkt, um 22200 Kathrein JOIN Punkte zu sammeln. Jetzt kostenlos anmelden und Mein Kathrein Konto anlegen und die ersten 10.000 Punkte sichern !
Type: | VWS 2500 |
Order no: | 20510098 |
Inputs: | 1 x terrestrial / 4 x Sat IF |
Decoupling strain: | -40 dB |
Max. Output level (2nd order interference products): | 104 ⁴) / 110 ³) dBµV |
Max. Output level (3rd order interference products): | 113 ²) / 115 ³) dBµV |
Permissible input voltage range: | 198 – 253 V |
Nominal input voltage: | 230 V (47 – 63 Hz) |
Nominal input power at 0-/150-/620-mA load: | 5,4/8,1/18 W |
Protection class | Protection class: | II (protective insulation) | IP 30 |
Frequency range: | 47-862 / 950-2150 MHz |
Available remote power supply current (input horiz. low): | 600 mA |
Max. Operating level for BK (up to 862 MHz) ⁵): | 98 dBµV |
Setting range of attenuation adjuster (1 dB steps): | 0 – 14 / 0 – 15 dB |
Amplification ¹): | 17 → 21 / 24 dB |
Adjustment range equalization: | 2/4/6 dB |
Voltage secondary (input horiz. low): | 18 V |
Connections: | F-Connectors |
Permissible ambient temperature: | -20 to +55 °C |
Dimensions (W x H x D): | 148 x 205 x 43 mm |
Packaging unit/weight: | 1 (10)/0.75 pc/kg |
¹) Frequency-dependent amplification (pre-emphasis)
²) 60-dB KMA according to EN 50083-5
³) 35-dB IMA according to EN 60728-3
⁴) 60-dB IMA according to EN 60728-3
⁵) According to EN 60728-3, 60-dB-CTB/CSO, CENELEC grid
- VWS 2500 - EU-Konformitätserklärung (Version: konformitätserklärung_vws 2500 - Größe: 95.41 KB) (10 downloads)
- VWS 2500 - Product data sheet (Version: 1 - Größe: 135.52 KB) (19 downloads)
- VWS 2500 - Produktdatenblatt (Version: 09/2023 - Größe: 134.81 KB) (88 downloads)
- VWS 2500 - Bedienungsanleitung | User Manual (Version: 1 - Größe: 1.40 MB) (376 downloads)